With DCU and D3-DSCBL-2 connected Base and CPU with DCU, or Thumbwheel interface With PROM Writer Unit (-lines) Star Washers Panel GroundB raidD3-16TA-2 0 0 200 400 0 0 0 0 Power Supplied Device 5V(mA) 9V(mA) 24V(mA) 24 V (mA) D3-05BDCD3-10BDC 900 900 2000 2000 500 500 None None Power Consumed. ) Compatibility Matrix Chart For DL05/06 PLCs I/O Modules Feed-through Modules Relay Modules Fuse Modules LED Modules D3-16TD2 system D3-04TAS 1 10 See Note 1 F3-08TAS-1 18 These modules are not supported by the ZIPLink wiring system D3-08TA-2 1 10 See Note 1 F3-16TA-2 18 These modules are not supported by the ZIPLink wiring D3-16TA-2 system D3-08TR 1 10 See Note 1 D3-16TR 18 These modules are not supported by the ZIPLink wiring system F3-08TRS-1 F3-08TRS-2. Please consider the D3-340 or D3-350 CPUs as a replacement. 0A 0. D3-16TA-2 New and Used available. (147g)Use . Join Product iQ. Anyone who installs or uses thisManual Number: D3--350--M DCS Center. AC or DC relay output modules. Consider BRX, Productivity, or CLICK PLC systems as upgrades. Automation Direct's 16 Point, 2 Common AC Powered Output Module is a commissioned product manufactured by Koyo and PLC Direct. In Stock! Automation Direct Koyo PLC Direct 8 Point 110/220 VAC Output. F3-16TA-2 D3-16TA-2 0 0 0 200 250 400 0 0 0 Power Supplied Device 5V(mA) 9V(mA) 24V(mA) 24 V (mA) D3-05BDCD3-10BDC 900 900 2000 2000 500 500 None None Power Consumed Device 5V(mA) 9V(mA) 24V(mA) External required Relay Output Modules F3-08TRS-1 F3-08TRS-2 D3-16TR 0 0 0 296 296 480 0 0 0 0 0 0 Analog Temperature and. D3-08TD2 See Note 1 F3-08TAS-1 18 See Note 2 D3-16TA-2 18 F3-08TRS-1 18 F3-08TRS-2 18 1These I/O modules have non-removable terminal blocks which can be 1-800-633-0405 For the latest prices, please check. WARNING Thank you for purchasing automation equipment from Automationdirect. Anyone who installs or uses this9 VDC Current Supplied 2. The example below shows a derating curve for a D3--16TD--1 discrete output module where the operating specifications are affected depending on ambient temperature. Step 3 Select the cable length by replacing the # symbol with: Blank = 0. (248g) Analog Modules D3--04AD 7 oz. D3-08TA-2 F3-16TA-2 D3-16TA-2 0 0 0 0 0 0 12 200 160 160 250 400 0 0 0 0 0 0 0 0 0 0 0 0 Power Supplied Device 5V(mA) 9V(mA) 24V(mA) 24 V (mA) D3-05B-1 D3-08B-1 D3-10B-1 D3-05BDC D3-10BDC D3-05B-NR D3-08B-NR D3-10B-NR D3-05BDC-NR D3-10BDC-NR 900 900 900 900 900 900 900 900 900 900 2000 2000 2000 2000 2000 2000 2000 2000. Programmable ControllersDerating Chart 0 4 8 12 16 Points 0 1 2 3 4 5 6 7 110VAC INPUT D3--16NA 6 C 1 3 I 0 2 4 5 7 7 0 2 4 C 1 3 5 6 II 0 1 2 3 4 5 6 7 II I CI CII 6 1 3 0 2 4 5 7 7 0 2 4 1. com™, doing business as, AutomationDirect. pdf Ziplink Wiring Diagrams. Productivity3000 discrete output module, 16-point, 120-240 VAC, 2 isolated common (s), 8 point (s) per common, 0. D3-FUSE-2: programmable controllers: directlogic spare fuse, 3a. DirectLOGIC DL305 discrete output module, 16-point, 24-240 VAC, 2 isolated common (s), 2 point (s) per common, 0. 2 oz. 5A/point 3A/common 6A/per module Max Leakage Current 4 mA @ 265VAC. in the tools and supplies, misc products category. D3-16TA-2 - 16-point, 24-240 VAC, 2 isolated common(s), 2 point(s) per common, 0. in the tools and supplies, misc products category. com™, doing business as, AutomationDirect. Anyone who installs or uses thisManual Number: D3--350--M DCS Center. D–2 SR44 Series Soft Starter User Manual 1st Ed, Rev A 09/2011. Programmable Controllerst1k-08b d3-16nd2-2 c0-11dre-d d4-ex c2-08d2-6c d4-16ta t1k-08trs c0-11dd2e-d ea7-s6m-s ea9-t12cl d4-08na d3-fill ea9-t7cl ea7-t15c c2-14d2 d3-422-dcu d2-16nd3-1 atm1700t c2-08dr-6v ea7-s6c d2-06bdc1-1 ss-106 d4-454 d3-16nd2f d4-16td1 d4-ss-106 d4-470 ea7-t6cl d0 d2-08na-2 d2-02pm d2-16td1-1 c2-03cpu-2 d2-16td2-2 d4-16nd2 d2-16td2-3 c0-02dr-d. D3-16TA-2. Link . 5A Max. pdf Ziplink Wiring Diagrams go to websiteTM Warning: When using the D2-12TR with the ZL-CM16TF1, do not exceed 5 Amps maximum per common. 1) Prices as of April 16, 2014. Rev C 8/02 Replaced F3--16TA--1 with F3--16TA--2 Rev D 1/2010 Made corrections throughout manual F3-16TA-2 has been retired as of 08/2022. 5A 1A L 5A Output Common 80--265VAC 9V 10 AmbientT emperature. AVERTISSEMENT Nousvousremercionsd’avoirachetél’équipementd’automatisationdeAutomationdirect. 5m, -1 = 1. We want your new automation equipment to operate safely. Discontinued item. Anyone who installs or uses this0. 1-800-633-0405 For the latest prices, please check AutomationDirect. 1 DCS Center. DC Input Modules D3-08ND2 DC Input $105. QR Code. None. 0. D3-05B-1 and D3-08TA-2 have been retired. Removable terminal block included. Programmable ControllersD3-08TA-2 AC Output <---> 8 265VAC 47-63Hz Max Leakage Current 1. A Column 1 Column 2 Column 3 Column 4 Column 5 Base # 0 Device Type 5 VDC (mA) 9VDC (mA) 24V(mA) B Current Supplied 5-slot Base D3-05BDC 1400 800 500 C Current Required CPU Slot D3-330 300 50 0 Slot 0 The document listing is represented by a combination of the UL CCN and File Number. com, a global distributor of electronics components. com™, doing business as, AutomationDirect. D Chapter 6: Discrete Input Modules Discrete Input Module Identification and Terminology. D3-05BDC base using 16-pt. D3-16TA-2 0 0 200 400 0 0 0 0 Power Supplied Device 5V(mA) 9V(mA) 24V(mA) 24 V (mA) D3-05BDCD3-10BDC 900 900 2000 2000 500 500 None None Power Consumed Device 5V(mA) 9V(mA) 24V(mA) External required Relay Output Modules F3-08TRS-1 F3-08TRS-2 D3-16TR 0 0 0 296 296 480 0 0 0 0 0 0 Analog Temperature and Thermocouple. Proximity Sensor Cross Reference. (255g) D3--16TR 8. 5A/point, 2 commons (isolated), removable terminal, 2 non-replaceable fuses AutomationDirect offers. 5A/POINT, 3A/COMMON, 6A/MODULE. 5A 0. of four outputs) Order D3-FUSE-4 (5 per pack) <---> D3-16TA-2 AC Output Outputs per Module 16 Commons per Module 2 (isolated) Operating Voltage 15-265VAC Output Type. 5A/point 3A/common 6A/per module Max Leakage Current 4 mA @. Check part details, parametric & specs and download pdf datasheet from datasheets. D3-08TA-2 F3-16TA-2 D3-16TA-2 0 0 0 0 0 0 12 200 160 160 250 400 0 0 0 0 0 0 0 0 0 0 0 0 Power Supplied Device 5V(mA) 9V(mA) 24V(mA) 24 V (mA) D3-05B-1 D3-08B-1 D3-10B-1 D3-05BDC D3-10BDC D3-05B-NR D3-08B-NR D3-10B-NR D3-05BDC-NR D3-10BDC-NR 900 900 900 900 900 900 900 900 900 900 2000 2000 2000 2000 2000 2000 2000 2000. F3-16TA-2 D3-16TA-2 0 0 0 200 250 400 0 0 0 0 Power Supplied Device 5V(mA) 9V(mA) 24V(mA) 24 V (mA) D3-05BDCD3-10BDC 900 900 2000 2000 500 500 None None Power Consumed Device 5V(mA) 9V(mA) 24V(mA) External required Relay Output Modules F3-08TRS-1 F3-08TRS-2 D3-16TR 0 0 0 296 296 480 0 0 0 0 0 0 Analog Temperature and. Wiring Diagram: Power Supply and Cable PLC DL 305 Type D3-16TA-2 AC Output I/O ModuleD3-16TA-2 0 0 200 400 0 0 0 0 Power Supplied Device 5V(mA) 9V(mA) 24V(mA) 24 V (mA) D3-05BDCD3-10BDC 900 900 2000 2000 500 500 None None Power Consumed Device 5V(mA) 9V(mA) 24V(mA) External required Relay Output Modules F3-08TRS-1 F3-08TRS-2 0 0 296 296 0 0 0 0 Analog Temperature and Thermocouple Modules F3-04ADSSiemens TI 305 | Siemens TI 405 | Siemens TI 505 And other related componentry Distributed Control Systems For Industrial Automation Siemens - Texas InstrumentsWARNING Thank you for purchasing automation equipment from Automationdirect. (200g) F3--08TRS--1 8. 30”(50mm) 2. PLC Library CD 4 I/O Modules 1,465 Folders 142 Allen-Bradley Automation Direct Cutler-Hammer GE Fanuc IDEC Mitsubishi Modicon Omron Siemens Telemecanique Toshiba PLC Library CD 4Allen-Bradley 1747 1762 1769 1791 CompactBlock ControlLogix. com™, doing business as, AutomationDirect. pdf Datasheet D3-08TA-2 (pdf, 342 KB) Download (pdf, 342 KB) pdf Datasheet D3-08TD1 (pdf, 202 KB. 0 30 0 0. Condition Codes; Global Website Policies; Reseller Info; Social Channels9 VDC Current Supplied 2. FollowOrder D3-FUSE-2 (5 per pack) retired F3-08TAS-1 AC Output $244. D3-08TA-1 D3-08TA-2 F3-16TA-2 D3-16TA-2 0 0 0 0 0 200 160 160 250 400 0 0 0 0 0 0 0 0 Power Supplied Device 5V(mA) 9V(mA) 24V(mA) 24 V (mA) D3-05B-1 D3-08B-1 D3-10B-1 D3-05BDC D3-10BDC D3-05B-NR D3-05BDC-NR 900 900 900 900 900 900 900 2000 2000 2000 2000 2000 2000 2000 500 500 500 500 500 500 500 100 100 100 None None 100. 0A 1. Product Category The Product Category, also known as the UL Category Description, describes the product classification under which an item or product is listed. Programmable Controllers Certified for CanadaF3-16TA-2 18 These modules are not supported by the ZIPLink wiring D3-16TA-2 system D3-08TR 1 10 See Note 1 D3-16TR 18 These modules are not supported by the ZIPLink wiring system F3-08TRS-1 F3-08TRS-2 All Tables Footnotes: 1 These I/O modules have non-removable terminal blocks which can be terminated using theWiring Solutions . — D3--16TA--2, 110--220 VAC Output Module — D3--08TR, Relay Output Module — F3--08TRS--1, Relay Output Module — F3--08TRS--2, Relay Output Module — D3--16TR, Relay Output Module. This document also may not show all models included in the listing. Consider BRX, Productivity, or CLICK PLC systems as upgrades. Note: These I/O addressing D3-16TA-2. F3-16TA-2 D3-16TA-2 0 0 0 0 200 160 250 400 0 0 0 0 0 Power Supplied Device 5V(mA) 9V(mA) 24V(mA) 24 V (mA) D3-05BDC D3-10BDC 900 900 2000 2000 500 500 None None Power Consumed Device 5V(mA) 9V(mA) 24V(mA) External required Relay Output Modules D3-08TR F3-08TRS-1 F3-08TRS-2 D3-16TR 0 0 0 0 360 296 296 480 0 0 0 0 0 0 0 0. Nominal Output is 6-24 VDC. DL305 ZL-3CBL2FR16 D3-16TA-2 ZL-CM16RL120A To download fullsize color . 5A 0. 9 VDC Current Supplied 2. 0 0 200 400 0 0 0 0. Multiple model numbers may indicate different products, different components within the products or both. 2 (internally connected) Input Voltage RangeThe DL305 PLC series is a small modular PLC that has been marketed by various name-brand PLC manufacturers for over 20 years. outputs, consider using the . Product Category The Product Category, also known as the UL Category Description, describes the product classification under which an item or product is listed. Consider BRX, Productivity, or CLICK PLC systems as upgrades. 7A 24 VDC Current Supplied 0. Consider BRX, Productivity, or CLICK PLC systems as. 5 VAC @ 0. Note: When used with the ZIPLink wiring system, relay outputs are derated not to exceed 2 Amps per point max. pdf Datasheet D3-16TA-2 (pdf, 343 KB) Download (pdf, 343 KB) pdf. If your application requires a lot of relay . D3-16TD2 has been retired as of 06/2022. d3-16ta-2 16 p t5- 20vaco u f3-08tas-1 8p t20- 15v ac isol edu . Anyone who installs or uses thisAUTOMATION DIRECT D3-16TA-2 / D316TA2 (USED TESTED CLEANED) $600. Cable Part No. 0. Link AC or . D3-16ND2-1 Discrete Input module has been discontinued as of 07/2021: Please consider the Productivity, BRX or CLICK Series of PLC systems as a replacement. 5A/point Maximum. We want your new automation equipment to operate safely. . We want your new automation equipment to operate safely. of four outputs) Order D3-FUSE-4 (5 per pack) <---> D3-16TA-2 AC Output <---> Outputs per Module 16 Commons per Module 2 (isolated) Operating Voltage 15-265VAC Output. com™, doing business as, AutomationDirect. 5VAC @ 0. We want your new automation equipment to operate safely. 9 oz. Requires P3-RTB removable terminal block or ZIPLink pre-wired cables. D3-08NA-2 10 DL305 PLC Output Module ZIPLink Selector ZIPLink Output Component Module Part No. com™, doing business as, AutomationDirect. D3-08TD2, D3-08ND2, D3-16TA-2, and D3-08NA-2 modules, as well as D3-340-EE EPROM chips have been discontin- D3-08TD2, D3-08ND2, D3-16TA-2, and D3-08NA-2 modules, as well as D3-340-EE EPROM chips have been discontin- ued with no replacement. Anyone who installs or uses thisManual Number: D3--350--M DCS Center. of four outputs) Order D3-FUSE-4 (5 per pack) <---> D3-16TA-2 AC Output <---> Outputs per Module 16 Commons per Module 2 (isolated) Operating Voltage 15-265VAC Output Type Triac Peak Voltage 265VAC AC Frequency 47-63Hz ON Voltage Drop 1. We want your new automation equipment to operate safely. Phone number: 1-877-854-3577 — Email: CEC@ul. com. 1 DCS Center. We want your new automation equipment to operate safely. com™, doing business as, AutomationDirect. Current 0. We want your new automation equipment to operate safely. com™, doing business as, AutomationDirect. 6--20 1 2 3 4 5 6 7 0 2 4 6 C 1 1 3 5 7 C 2 11 0V AC IN PU T D3 --08N A--1 C1 0 1 2 3 4 5 6 7 C2 110VAC 110VAC 110VAC Input Common 2. Consider BRX, Productivity, or CLICK PLC systems as upgrades. We want your new automation equipment to operate safely. com™, doing business as, AutomationDirect. Consider BRX, Productivity, or CLICK PLC systems as upgrades. D3-16TA-2 New and Used available. com. Link . com™, doing business as, AutomationDirect. 2 oz. D3-16TD1-1 Output module has been discontinued with no replacement. WARNING Thank you for purchasing automation equipment from Automationdirect. 5A 0. — D3--16TA--2, 110--220 VAC Output Module — D3--08TR, Relay Output Module — F3--08TRS--1, Relay Output Module — F3--08TRS--2, Relay Output Module — D3--16TR, Relay Output Module. Anyone who installs or uses thisof four outputs) Order D3-FUSE-4 (5 per pack) <---> D3-16TA-2 AC Output <---> Outputs per Module 16 Commons per Module 2 (isolated) Operating Voltage 15-265VAC Output Type Triac Peak Voltage 265VAC AC Frequency 47-63Hz ON Voltage Drop 1. com™, doing business as, AutomationDirect. Use this cross-reference table if you're looking for the equivalent PLC Direct parts for your "old" GE or TI/Siemens PLC system. Wiring Diagram: Power Supply and Cable PLC DL 305 Type D3-16TA-2 AC Output I/O ModuleProduct Category The Product Category, also known as the UL Category Description, describes the product classification under which an item or product is listed. 0 0 296 296 0 0 0 0. 2000. CurrentA Column 1 Column 2 Column 3 Column 4 Column 5 Base # 0 Device Type 5 VDC (mA) 9VDC (mA) 24V(mA) B Current Supplied 5-slot Base D3-05BDC 1400 800 500 C Current Required CPU Slot D3-330 300 50 0 Slot 0d3-16ta-2 d3-16td1-1 d3-16td1-2 d3-16td2 d4-08nd3s d4-16na d4-16na-1 d4-16nd2 d4-16nd2f d4-16ne3 d4-16ta d4-16td1 d4-16td2 d4-32nd6-1 d4-32nd3-2 d4-32td1 d4-32td1-1 d4-32td2 d4-64nd2 d4-64td1 f3-08tasSiemens TI 305 | Siemens TI 405 | Siemens TI 505 And other related componentry Distributed Control Systems For Industrial Automation Siemens - Texas InstrumentsDerating Chart 0 4 8 12 16 Points 0 1 2 3 4 5 6 7 RELAYO UTPUT D3--16TR 6 C 1 3 I 0 2 4 5 7 7 0 2 4 C 1 3 5 6 II 0 1 3 4 5 7 II I CI CII 6 1 3 0 2 4 5 7 7 0 2 4 1 3 5. pio DL305 D3-16TA-2. I/O modules 5-slot local Total I/O: 64 D3-05BDC base using 8-pt. D D3--08TD1, 24 VDC Output Module Outputs per module 8 (current sinking) Minimum load 1mA t1k-08b d3-16nd2-2 c0-11dre-d d4-ex c2-08d2-6c d4-16ta t1k-08trs c0-11dd2e-d ea7-s6m-s ea9-t12cl d4-08na d3-fill ea9-t7cl ea7-t15c c2-14d2 d3-422-dcu d2-16nd3-1 c2-08dr-6v ea7-s6c ss-106 d4-454 d3-16nd2f d4-16td1 d4-ss-106 ea7-t6cl p3-8ad4da-2 d0 d2-08na-2 d2-16td1-1 c2-03cpu-2 d2-16td2-2 d4-16nd2 d2-16td2-3 c2-08ar-6c t1k-16tr d3-32nd3 c0-02dr. 2021 08. 5A 0. Current 0. WARNING Thank you for purchasing automation equipment from Automationdirect. Anyone who installs or uses thisManual Number: D3--350--M DCS Center. 1 DCS Center. com™, doing business as, AutomationDirect. WARNING Thank you for purchasing automation equipment from Automationdirect. 8A 2. ple and logical termination for 2 or3-wire sensors or other devices, and offer visual indication of device input status for quick troubleshooting. (200g) F3--08TRS--1 8. comMC,enfaisantdesaffaires comme,AutomationDirect. D3-08TD2, D3-08ND2, D3-16TA-2, and D3-08NA-2 modules, as well as D3-340-EE EPROM chips have been discontin- D3-16TA-2 PLCs/Machine Control from AUTOMATION DIRECT In Stock, Order Now! Same Day Shipping, 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, DIRECTLOGIC DL305 DISCRETE OUTPUT MODULE, 16-POINT, 24-240 VAC, 2 ISOLATED COMMON(S), 2 POINT(S) PER COMMON, 0. 5A Auxiliary 24 VDC Output 100mA max None 100mA max 100mA max None Run Relay 250VAC 4A (resistive load) 250VAC 4A (resistive load) 250VAC 4A (resistive load) 250VAC 4A (resistive load) 250VAC, 4A (resistive load) Fuses 2A (250V) Non. com™, doing business as, AutomationDirect. PLC Library CD 4 I/O Modules 1,465 Folders 142 Allen-Bradley Automation Direct Cutler-Hammer GE Fanuc IDEC Mitsubishi Modicon Omron Siemens Telemecanique Toshiba PLC Library CD 4Allen-Bradley 1747 1762 1769 1791 CompactBlock ControlLogix. Derating Chart 0 4 8 12 16 Points 0 1 2 3 4 5 6 7 RELAYO UTPUT D3--16TR 6 C 1 3 I 0 2 4 5 7 7 0 2 4 C 1 3 5 6 II 0 1 3 4 5 7 II I CI CII 6 1 3 0 2 4 5 7 7 0 2 4 1 3 5. NOTE: For the latest information on agency approvals, check our Web site. Link . Design conditions Max. Advanced Search. WARNING Thank you for purchasing automation equipment from Automationdirect. Link . We want your new automation equipment to operate safely. 87” (73mm) with relay Spare relay ZL-RELAY-120 Spare Relay Clips ZL-RELAY-KIT. D3-16TA-2 AC Output Retired Minimum Load 10mA @ 15VAC Base Power Required* 9V 25mA max/ON pt. ZIP. # Cables are available in 0. power requirements. 0A 2. Consider BRX, Productivity, or CLICK PLC systems as upgrades. Consider BRX, Productivity, or CLICK PLC systems as upgrades. WARNING Thank you for purchasing automation equipment from Automationdirect. D3-08TA-2 F3-16TA-2 D3-16TA-2 0 0 0 0 0 0 12 200 160 160 250 400 0 0 0 0 0 0 0 0 0 0 0 0 Power Supplied Device 5V(mA) 9V(mA) 24V(mA) 24 V (mA) D3-05B-1 D3-08B-1 D3-10B-1 D3-05BDC D3-10BDC D3-05B-NR D3-08B-NR D3-10B-NR D3-05BDC-NR D3-10BDC-NR 900 900 900 900 900 900 900 900 900 900 2000 2000 2000 2000 2000 2000 2000 2000. 1 DCS Center. ZIP. Anyone who installs or uses thisManual Number: D3--350--M DCS Center. ) Compatibility Matrix Chart For 05/06 PLCs I/O Modules Feed-through ModulesRelay Modules Fuse Modules LED ModulesSinking and Sourcing Concepts A PPENDIX Appendix 27–3 SINKING AND SOURCING CONCEPTS Common terminals and how to use them In order for a PLC I/O circuit to operate, current must enter at one terminal andModel Number(s) Model numbers included in the listing. for use with d3-04tas discrete output module. 0m, -2 = 2. Check Web site for most current prices. The DL305 PLC series is a small modular PLC that has been marketed by various name-brand PLC manufacturers for over 20 years. 5A 0. This seller has been contacted 2 times in the last week. Links to reduce . 2000. For every 8 points on the device, there is an isolated output common. Automationdirect's D3-16TA-2 is a specifying an i/o wiring system. Call Now! D3-08TD1 is a DirectLogic DL305 discrete sinking 8 output point module. 00 Outputs per Module 8 (current sinking) Commons per Module 2 (internally connected) Operating Voltage 5–24 VDC Output Type NPN (open collector) Peak Voltage 45VDC AC Frequency ON Voltage Drop 0. Anyone who installs or uses thisManual Number: D3--350--M DCS Center. DIRECT LOGIC. 16 1 5 20 50 VCE =20V 125 125 125 Test Circuit for Frequency Response TestC ircu fo R pon me Part No. A list of PLCs supported by DirectSOFT. ZIP. 1 DCS Center. 26–52 Terminal Blocks and Wiring Solutions 1-800-633-0405 Specifying an I/O Wiring System, (cont. Note: These I/O addressing configurations are for the bases with “-1” on the end of the part number. We want your new automation equipment to operate safely. D3-08ND2 DC Input . Contact Us. F3-16TA-2 D3-16TA-2 0 0 0 200 250 400 0 0 0 Power Supplied Device 5V(mA) 9V(mA) 24V(mA) 24 V (mA) D3-05BDCD3-10BDC 900 900 2000 2000 500 500 None None Power Consumed Device 5V(mA) 9V(mA) 24V(mA) External required Relay Output Modules D3-08TR F3-08TRS-1 F3-08TRS-2 D3-16TR 0 0 0 0 360 296 296 480 0 0 0 0 0 0 0 0 Analog. D3-08TD2, D3-08ND2, D3-16TA-2, and D3-08NA-2 modules, as well as D3-340-EE EPROM chips have been discontin- ued with no replacement. e Là Nhà Phối Phối Chính Thức Hãng Koyo Plc Việt Nam. 5A 0. CNC Specialty Store Constructor 10 Drawing Software PLC Symbol Library option. (252g) F3--08TRS--2 9 oz. in the tools and supplies, misc products category. A Column 1 Column 2 Column 3 Column 4 Column 5 Base # 0 Device Type 5 VDC (mA) 9VDC (mA) 24V(mA) B Current Supplied 5-slot Base D3-05BDC 1400 800 500 C Current Required CPU Slot D3-350 500 0 0 Slot 0 D3-16NE3 0 130 Slot 1 D3-16NE3 0 130 0 Slot 2 D3-08TA-1 0 160 0 Slot 3 D3-08TA-1 0 160 0 D Other Handheld prog D2-HPP 200 0 0 t1k-08b d3-16nd2-2 c0-11dre-d d4-ex c2-08d2-6c d4-16ta t1k-08trs c0-11dd2e-d ea7-s6m-s ea9-t12cl d4-08na d3-fill ea9-t7cl ea7-t15c c2-14d2 d3-422-dcu d2-16nd3-1 c2-08dr-6v ea7-s6c ss-106 d4-454 d3-16nd2f d4-16td1 d4-ss-106 ea7-t6cl p3-8ad4da-2 d0 d2-08na-2 d2-16td1-1 c2-03cpu-2 d2-16td2-2 d4-16nd2 d2-16td2-3 c2-08ar-6c t1k-16tr d3-32nd3 c0-02dr. Retired. 1 DCS Center. 0 10 0 0. 8/common 0. 15-220V AC output module, 0. Join Product iQ. 4 4” (101,6mm) 4” (101,6mm) BOTTOM TOP BOTTOM TOP BOTTOM TOP TOP Mounting Orientation: OK! AC-Powered Relay Modules Model Number(s) Model numbers included in the listing. We want your new automation equipment to operate safely. 5VAC @ 0. 02 0. 5 oz. We want your new automation equipment to operate safely. Dimensions(lxwxh) 11. F3-16TA-2 D3-16TA-2 0 0 0 200 250 400 0 0 0 Power Supplied Device 5V(mA) 9V(mA) 24V(mA) 24 V (mA) D3-05BDCD3-10BDC 900 900 2000 2000 500 500 None None Power Consumed Device 5V(mA) 9V(mA) 24V(mA) External required Relay Output Modules D3-08TR F3-08TRS-1 F3-08TRS-2 D3-16TR 0 0 0 0 360 296 296 480 0 0 0 0 0 0 0 0 Analog. 1 DCS Center. Programmable Controllers Certified for CanadaDL305 ZL-3CBL2FR16 D3-16TA-2 ZL-CM16RL120A To download fullsize color . (255g) D3--16TR 8. Join Product iQ. 5A/point 3A/common 6A/per module Max Leakage Current 4 mA @ 265VAC. 5A/point, 3A/common, 6A/module. Consider BRX, Productivity, or CLICK PLC systems as upgrades. com, a global distributor of electronics components. Programmable Controllers Certified for Canadaof four outputs) Order D3-FUSE-4 (5 per pack) <---> D3-16TA-2 AC Output Outputs per Module 16 Commons per Module 2 (isolated) Operating Voltage 15-265VAC Output Type Triac Peak Voltage 265VAC AC Frequency 47-63Hz ON Voltage Drop 1. 10 0. WARNING Thank you for purchasing automation equipment from Automationdirect. 1 REV 1. 5A Auxiliary 24 VDC Output 100mA max None 100mA max 100mA max None Run Relay 250VAC 4A (resistive load) 250VAC 4A (resistive load) 250VAC 4A (resistive load) 250VAC 4A (resistive load) 250VAC, 4A (resistive load) Fuses 2A (250V) Non. pio Output DL305 D3-02DA. D3-08NA-2 10 DL305 PLC Output Module ZIPLink Selector ZIPLink Output Component Module Part No. Line chokes can be reused if field settings remain unchanged I/O extension board SDCS-IOE-1 has to be exchanged. 5A Max. 5 oz. 1 DCS Center. 5A/point, 3A/common, 6A/module. pdf Datasheet D3-16TA-2 (pdf, 343 KB) Download (pdf, 343 KB) pdf Datasheet D3-16TD1-1 (pdf, 377 KB. We want your new automation equipment to operate safely. 00 • D3-FUSE-6 – Fuses for F3-08TRS-2 $23. *These I/O modules have non-removable terminal blocks which can be terminated using the ZL-CBL24-N cable and the ZL-RTB20 module of the ZIPLinkD3-08TAS-1, F3-16TA-1 and F3-16TA –2 $23. 00 Fixed terminal block Choose your modules Now that you understand the factors that affect your choice of an I/O module,D3-08TA-2 F3-16TA-2 D3-16TA-2 0 0 0 0 0 0 12 200 160 160 250 400 0 0 0 0 0 0 0 0 0 0 0 0 Power Supplied Device 5V(mA) 9V(mA) 24V(mA) 24 V (mA) D3-05B-1 D3-08B-1 D3-10B-1 D3-05BDC D3-10BDC D3-05B-NR D3-08B-NR D3-10B-NR D3-05BDC-NR D3-10BDC-NR 900 900 900 900 900 900 900 900 900 900 2000 2000 2000 2000 2000 2000 2000 2000. D3-08TA-2 F3-16TA-2 D3-16TA-2 0 0 0 0 0 0 12 200 160 160 250 400 0 0 0 0 0 0 0 0 0 0 0 0 Power Supplied Device 5V(mA) 9V(mA) 24V(mA) 24 V (mA) D3-05B-1 D3-08B-1 D3-10B-1 D3-05BDC D3-10BDC D3-05B-NR D3-08B-NR D3-10B-NR D3-05BDC-NR D3-10BDC-NR 900 900 900 900 900 900 900 900 900 900 2000 2000 2000 2000 2000 2000 2000 2000. com™, doing business as, AutomationDirect. 0A 0. 400mA max 24V N/A See page tDL3-26 for part numbers of ZIPLink. 6 V(Rms) @ 1. D3-08TD1 is a DirectLogic DL305 discrete sourcing 8 output point module. Cable Part No. PLC DL 305 Type D3-16TA-2 AC Output I/O Module. 26–50 Terminal Blocks and Wiring Solutions 1-800-633-0405 Specifying an I/O Wiring System Compatibility Matrix Chart for DL205/305/405 PLCs I/O Modules Feed-through Modules AC-Powered Relay Modules DC-Powered Relay Modulest1k-08b d3-16nd2-2 c0-11dre-d d4-ex c2-08d2-6c d4-16ta t1k-08trs c0-11dd2e-d ea7-s6m-s ea9-t12cl d4-08na d3-fill ea9-t7cl ea7-t15c c2-14d2 d3-422-dcu d2-16nd3-1 c2-08dr-6v ea7-s6c ss-106 d4-454 d3-16nd2f d4-16td1 d4-ss-106 ea7-t6cl p3-8ad4da-2 d0 d2-08na-2 d2-16td1-1 c2-03cpu-2 d2-16td2-2 d4-16nd2 d2-16td2-3 c2-08ar-6c t1k-16tr d3-32nd3 c0. AC or DC relay output modules. Wiring System for CLICK PLCs Step 1 Locate the CLICK CPU module or I/O module part number. If your application requires a lot of relay . Cable Part No. 1 DCS Center. : LTV-816X (M、S-TA1)-D3-TX SERIES Page : 10 of 13 BNS-OD. 5 oz. We want your new automation equipment to operate safely. Siemens TI 305 | Siemens TI 405 | Siemens TI 505 And other related componentry Distributed Control Systems For Industrial Automation Siemens - Texas InstrumentsManual Number: D3--350--M DCS Center. Tested and 2-Year Warranty. (154g) F3--08TEMP 5. 1 DCS Center. 0 0 200 400 0 0 0 0. ZIP. 0A 2. 8A 2. 0A 2. Please consider Productivity, BRX, or CLICK PLC systems asSlot 1 D3-16NE3 0 130 0 Slot 2 F3-16TA-1 0 160 0 Slot 3 F3-16TA-1 0 160 0 D Other Handheld prog D3-HPP 50 50 0 E Maximum Current Required 360 680 0 F Remaining Current 1040 120 500 D3-16NE3 POWER BUDGET 1-800-633-0405. WARNING Thank you for purchasing automation equipment from Automationdirect. (200g) F3--08TRS--1 8. DC Input Modules D3-08ND2 F3-16ND3F. D3-16TA-2 specifics: 16 AC outputs (15~265 VAC) D3--16NE3 16 D3--16TA--2 16 D3--02DA 16 * This is a 4-point module, but each slot is assigned a minimum of 8 I/O points. 5 VAC @ 0. D3-16TA-2; F3-16TA-2; ZL-CM40; ZL-CM20; Browser extension. 5m, -1 = 1. DIRECT LOGIC. Links to reduce . see the In-Depth section. Cable Part No. 5a/point, 8 commons (isolated) f3-16ta-2 16pt 20-125vac output module 1. 2 oz. 0 0 10 148 112 68 0 0. Marked set by hdittrich. 57”(294mm) 2. D3-16TA-2 - 16-point, 24-240 VAC, 2 isolated common(s), 2 point(s) per common,. 87” (73mm) with relay Spare relay ZL-RELAY-120 Spare Relay Clips ZL-RELAY-KIT. Choose from 23 different discrete modules, including DC in, AC in, DC out, AC out and relay out. 26. 5A Max. D3-08TA-1 D3-08TA-2 F3-16TA-2 D3-16TA-2 0 0 0 0 0 200 160 160 250 400 0 0 0 0 0 0 0 0 Power Supplied Device 5V(mA) 9V(mA) 24V(mA) 24 V (mA) D3-05B-1 D3-08B-1 D3-10B-1 D3-05BDC D3-10BDC D3-05B-NR D3-05BDC-NR 900 900 900 900 900 900 900 2000 2000 2000 2000 2000 2000 2000 500 500 500 500 500 500 500 100 100 100 None None 100. 1 REV 1. D3-08TD2 See Note 1 F3-08TAS-1 18 See Note 2 D3-16TA-2 18 F3-08TRS-1 18 F3-08TRS-2 18 1These I/O modules have non-removable terminal blocks which can be ModuleD3-16TA-2. D3-08TD2, D3-08ND2, D3-16TA-2, and D3-08NA-2 modules, as well as D3-340-EE EPROM chips have been. Links to reduce . ) Compatibility Matrix Chart For DL05/06 PLCs I/O Modules Feed-through Modules Relay Modules Fuse Modules LED ModulesSiemens TI 305 | Siemens TI 405 | Siemens TI 505 And other related componentry Distributed Control Systems For Industrial Automation Siemens - Texas InstrumentsD3-08TD2, D3-08ND2, D3-16TA-2, and D3-08NA-2 modules, as well as D3-340-EE EPROM chips have been discontin-ued with no replacement. 2 ounces. 5A 0. Inputs per Module. D3-16TA-2 - 16 pt. 1 DCS Center. Links to reduce . DISCONTINUED BY MANUFACTURER, DIRECTLOGIC DL305 DISCRETE OUTPUT MODULE, 16-POINT, 24-240 VAC, 2 ISOL. 1 DCS Center. 0. 7 oz. ZIP. Removable. pioManual Number: D3--350--M DCS Center. 1 DCS Center. 7 oz. WARNING Thank you for purchasing automation equipment from Automationdirect. pdf Ziplink Wiring Diagrams. 00 Outputs per Module 16 Commons per Module 2 (isolated) Operating Voltage 15–265 VAC Output Type Triac Peak Voltage 265VAC AC Frequency 47–63 Hz ON Voltage Drop 1. com™, doing business as, AutomationDirect. Automationdirect's ZL-CM40 is a specifying an i/o wiring system. in the tools and supplies, misc products category. DC relay output modules. 5A 0. We want your new automation equipment to operate safely. We want your new automation equipment to operate safely. Anyone who installs or uses this26–50 Terminal Blocks and Wiring Solutions 1-800-633-0405 Specifying an I/O Wiring System Compatibility Matrix Chart for DL205/305/405 PLCs I/O Modules Feed-through Modules AC-Powered Relay Modules DC-Powered Relay ModulesManual Number: D3--350--M DCS Center. Nam - O976O21887 Category Model Plc_D0 D0-Cbl Plc_D0 D0-Devnets Plc_D0 D0-Hsio Plc_D0 D0-01Mc . 7A 24 VDC Current Supplied 0. Use this cross-reference table if you're looking for the equivalent PLC Direct parts for your "old" GE or TI/Siemens PLC system.